型号系列:SRG10系列
商品类型:High voltage power supply
产品品牌:赛瑞尔达
产品描述:SRG10 Series High-Voltage DC Switching Power SupplyPerformance FeaturesConstant
咨询电话:13655813499
Model Input Voltage (V) Output Power (W) Output Voltage (KV) Output Current (mA) SRG10-10K AC220 10% 100 - 100 - 1 SRG10-15K AC220 10% 100 - 150 - 0.66 SRG10-20K AC220 10% 100 - 200 - 0.5 SRG10-25K AC220 10% 100 - 250 - 0.4 SRG10-30K AC220 10% 100 - 300 - 0.33 SRG10-35K AC220 10% 100 - 350 - 0.28
Constant voltage and constant current power supply, with voltage and current values presettable;
Output voltage and current adjustable from 0;
Good linear relationship of signal-controlled output;
Provides various special customization functions;
The output power is related to the size of the load connected to the output. Before the internal protection limit is reached, the higher the voltage, the greater the output power;
External control (high/low level or a small switch) can be added to make the high-voltage output controllable, and low-frequency intermittent pulse high voltage can also be output.
Testing and aging of lamps such as LED and energy-saving lamps
开关电源、电源适配器
光伏、逆变器测试老化
航空航天、国防军工
电动车电机、控制器、直流马达测试及老化
电容器、电阻、继电器、晶体管、传感器等电子器件
电解、电镀、腐蚀铝箔加工等;液晶屏、触摸屏等显示器
汽车电子、直流电机、电机控制器、点烟器、影音测试老化等
| 参数类别 | 参数值 | 备注 | ||
|---|---|---|---|---|
| Input parameters | ||||
| Input | Voltage range | 200-242VAC | Note 1 | |
| Power supply type | AC/DC | |||
| Performance parameters | ||||
| Performance | Efficiency | 85%-92% | ||
| Inrush current | Soft start | |||
| Voltage accuracy | ≤1% | |||
| Current accuracy | ≤1% | |||
| Voltage display | 4.5-digit 19.999, LED digital tube display | |||
| Current display | None | |||
| Ripple and noise (r.m.s) | <1% (mVp-p) | Note 2 | ||
| Adjustment method | Knob adjustment | |||
| Special notes | 1: The current used must not exceed the rated current; 2: When used at a voltage higher than the rated voltage, the total output power must be less than the rated power | |||
| Protection function | ||||
| Protection | Overcurrent protection | Current limiting protection mode | Note 3 | |
| Over-temperature protection | When the internal heat sink temperature reaches 70-80°C, the power supply activates thermal protection and stops output. | |||
| Overvoltage protection | Limit the maximum voltage output and issue an alarm. | |||
| Overload protection | Set maximum power, over-power protection alarm | |||
| Short circuit protection | Output short circuit, power supply starts current limiting protection | |||
| Safety features | ||||
| Safety | Withstand Voltage | Input to output ≥1.5KVAC; input to ground ≥1.5KVAC; output to ground ≥1.5KVAC; 60S | ||
| Insulation Impedance | ≥50M Ohms/500VDC | |||
| Environmental Parameters | ||||
| Environment | Cooling method | Forced air cooling, fan start-up temperature 45℃ | ||
| Operating temperature and humidity | -25~+60℃, 20~90%RH non-condensing | |||
| Storage temperature and humidity | -25~+70℃, 20~95%RH non-condensing | |||
| Altitude | Altitude ≤2000m requires no derating; operating temperature decreases by 1℃ for every 100m increase | |||
| Shock resistance | 10~500Hz, 2G, 10 minutes/cycle, 60 minutes each for X, Y, and Z axes | |||
| Other parameters | ||||
| Other | Weight | Net weight 1.65 kg | ||
| Packaging | Neutral white box or yellow box | |||
| Dimensions (L×W×H) | 195*175*70 mm | |||
| After-sales | Under normal working conditions according to the instructions, the warranty is one year; under abnormal conditions, such as: illegal operation not according to the instructions, fire, water ingress, lightning strike, electric shock, etc., are not covered by the warranty. | |||